Friday, October 10, 2014

uploaded

CAE 432 ProjectThis project concerns design of a one-story parking garage in a 90x120-foot land in a North Chicago suburb (Cook County). Cars will be using both the ground level and the roof. The suggested design for the roof is a series of simply-supported girders on brackets (which are attached to columns). Secondary members are in the form of pre-fabricated T-section joists. A shear wall system is considered for the wind load effects (note: because of the shear walls, your design will be only for DL and LL).
Document Preview:

CAE 432 ProjectThis project concerns design of a one-story parking garage in a 90x120-foot land in a North Chicago suburb (Cook County). Cars will be using both the ground level and the roof. The suggested design for the roof is a series of simply-supported girders on brackets (which are attached to columns). Secondary members are in the form of pre-fabricated T-section joists. A shear wall system is considered for the wind load effects (note: because of the shear walls, your design will be only for DL and LL). As a minimum, the following tasks are required:Develop a schematic design for the facility. Include the locations of columns and show girders with a few cross sections (that will also show single footings for columns).Conduct a preliminary design and identify all loads (DL and LL). Decide on the type of materials to be used.Design a typical girder.Design a typical column.Design a typical bracket.Design a typical footingPrepare detail drawings for the beam, column and footing you designed.Bonus points: Additional points will be given for the design of the T-section joists and design of a typical foundation.Your calculation sheets must be clear and written on suggested calculation sheets. Include a section in your report (up-front) for the specifications summarizing material properties, pertinent codes and specifications, assumptions made, etc. Also include a critique, at the end of your report, summarizing what you found as areas that perhaps more work would have been needed and/or design should have been done differently.Grading will be based on:Completeness of the tasks requested.Correctness of calculations.Reasonableness of your design.Presentation of your project (as your final report).Professionalism in preparing your calculation sheets and drawings.ed.Bonus points: Additional points will be given for the design of the T-section joists and design of a typical foundation.Your calculation...

No comments:

Post a Comment